Triplett TDR Manuale Utente Pagina 7

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 21
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 6
Page 6
3. Specications
Approximate Range Coaxial Cable: 6400ft max (1999m)
Structured Wiring: 2500ft max (750m)
Telephone Cable: 2500ft max (750m)
Resolution 0.1ft < 100ft & 1ft > 100ft
Accuracy +/- 3% or 1.5ft
Vp Range 0 to 99%
Cable Library 39 Standard Cable Types
Tone Generator Oscillating between 810Hz and 1110Hz
Display Alpha-numeric LCD
Connector BNC
Battery 9v PP3 Alkaline cell
Battery Life Better than 2000 tests
Temperature 32 to 112 deg F (0 to 40 deg C)
Storage Temp. 0 to 150 deg F
Dimensions 7.9” x 3.1” x 1.4”
Weight less than 0.55lb
Safety IEC1010-1
EMC To EU directives
UL, CUL and CE Approved
4. Principles of Operation
The TDR works by measuring the time taken for a signal to travel to the far
end of the cable (or to an intermediate fault) and to return.
The velocity at which the signal is transmitted (Velocity of Propagation ie.
Vp) will depend on the characteristics of the cable under test.
Vedere la pagina 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 20 21

Commenti su questo manuale

Nessun commento